CDA · 8% of the exam
RHS: Infection Prevention and Control practice questions
10 free RHS: Infection Prevention and Control questions for the Certified Dental Assistant (CDA) Exam exam, each with the correct answer and an explanation for every option.
What this domain covers
Infection control applied to radiography: protecting sensors, film and equipment, and handling receptors without cross-contaminating.
- Exam weight
- 8%
- On a real exam
- ≈ 20 questions
- In our bank
- 46 questions
Topics that come up most
- Barriers for digital sensors and PSP plates
- Disinfecting the tube head, control panel and chair
- Handling contaminated film packets
- Infection control in the darkroom and processor
- PPE during imaging procedures
How to study it
Walk through an imaging appointment from set-up to clean-up and note where contamination can spread; questions follow that same order.
Sample RHS: Infection Prevention and Control questions
Try each one before opening the answer. Original questions written to the official exam objectives.
Question 1
While wearing contaminated gloves, the operator should not touch:
- AUncovered charts or keyboards
- BThe patient's receptor holder
- CThe covered tubehead
- DThe covered exposure button
Show answer and explanation
Answer: A) Uncovered charts or keyboards
- ACorrect. Use barriers or overgloves.
- BIncorrect. That's expected during exposure.
- CIncorrect. That's barrier-protected.
- DIncorrect. That's barrier-protected.
Question 2
Partway through a series of intraoral exposures, the assistant must enter information on a chairside keyboard that has no barrier. The assistant is wearing gloves that are contaminated with saliva. What is the most appropriate action?
- ARemove the gloves and perform hand hygiene before typing on the keyboard
- BWipe the gloved fingertips with a disinfectant wipe, then type on the keyboard
- CType with the gloved hands, then place a barrier on the keyboard for the next patient
- DType with the gloved hands and disinfect the keyboard at the end of the day
Show answer and explanation
Answer: A) Remove the gloves and perform hand hygiene before typing on the keyboard
Computer equipment in the operatory is a clinical contact surface. It must be covered with a barrier that is changed between patients, or touched only after contaminated gloves are removed.
- ACorrect. Chairside computer equipment is a clinical contact surface. If it has no barrier, it should not be touched with contaminated gloves. Removing gloves and performing hand hygiene before touching it prevents cross-contamination.
- BIncorrect. CDC advises against washing or disinfecting gloves. Wiping them does not reliably decontaminate them and can damage the glove material.
- CIncorrect. The keyboard is already contaminated once it is touched with contaminated gloves. Putting a barrier on afterward covers the contamination rather than preventing it.
- DIncorrect. Clinical contact surfaces must be barrier-protected or disinfected between patients. Waiting until the end of the day allows cross-contamination.
Question 3
Before exposing a series of intraoral images, which surfaces should the dental assistant cover with surface barriers?
- AThe tubehead, PID, and exposure control panel or button
- BThe patient's lead apron and thyroid collar only
- CThe intraoral sensor only, since the tubehead touches only intact skin
- DThe processing area countertop only, where exposed receptors are unwrapped
Show answer and explanation
Answer: A) The tubehead, PID, and exposure control panel or button
Any surface touched with contaminated gloves during exposures, such as the tubehead, PID, and control panel, should be covered with a barrier, or cleaned and disinfected after each patient.
- ACorrect. Gloved hands touch these surfaces during exposures. CDC advises covering radiography equipment such as the tubehead and control panel with barriers, or cleaning and disinfecting it after each patient.
- BIncorrect. The apron is cleaned and disinfected after use, but the surfaces most touched during exposures are the tubehead, PID, and controls. Protecting only the apron leaves them contaminated.
- CIncorrect. The tubehead is a noncritical item, but contaminated gloves still touch it, so it needs a barrier or cleaning and disinfection between patients. The sensor also needs its own FDA-cleared barrier.
- DIncorrect. The processing area also needs aseptic handling, but this does not protect operatory equipment that contaminated gloves touch during exposures.
Question 4
During a full-mouth radiographic survey, the assistant adjusts the dental chair several times while wearing gloves that have touched the patient's mouth. What is the main reason the chair controls should be covered with a surface barrier?
- AThe controls are hard to clean and are touched with saliva-contaminated gloves
- BThe barrier shields the chair's electronics from scatter radiation during exposures
- CThe barrier lets the assistant adjust the chair without wearing gloves
- DThe barrier removes the need to check the surface underneath when it is taken off
Show answer and explanation
Answer: A) The controls are hard to clean and are touched with saliva-contaminated gloves
During imaging, gloved hands contaminated with saliva touch the chair controls, which are hard to clean. CDC recommends covering such surfaces with barriers, changing them between patients, and cleaning and disinfecting the surface if it is soiled underneath.
- ACorrect. CDC names switches on dental chairs as clinical contact surfaces that are hard to clean. These surfaces should be covered with an FDA-cleared barrier, and the barrier changed between patients.
- BIncorrect. A thin plastic barrier gives no radiation shielding. Its purpose is infection control: it keeps contamination off a surface that is hard to clean.
- CIncorrect. Gloves must be worn when taking radiographs and handling contaminated film packets or sensors. A barrier on the controls does not replace hand protection.
- DIncorrect. CDC says to look at the surface after removing the barrier. If it is soiled, clean and disinfect it before the next patient.
Question 5
A digital radiography sensor cannot tolerate heat sterilization or high-level disinfection. It was covered with an FDA-cleared barrier during exposures. After the barrier is removed, what is the minimum processing CDC recommends before the next patient?
- AClean it and disinfect it with an EPA-registered intermediate-level (tuberculocidal) hospital disinfectant
- BPlace a new barrier over it; the old barrier kept it from becoming contaminated
- CWipe it with a low-level disinfectant that has no tuberculocidal claim
- DWipe it with a dry gauze square to remove saliva, then re-barrier it
Show answer and explanation
Answer: A) Clean it and disinfect it with an EPA-registered intermediate-level (tuberculocidal) hospital disinfectant
Digital sensors are semicritical. If one cannot be heat-sterilized or high-level disinfected, CDC calls at minimum for an FDA-cleared barrier plus cleaning and intermediate-level (tuberculocidal) disinfection between patients.
- ACorrect. For sensors that cannot be heat-sterilized or high-level disinfected, CDC's minimum is barrier protection plus an EPA-registered hospital disinfectant with intermediate-level (tuberculocidal) activity between patients.
- BIncorrect. Barriers reduce contamination but can fail. CDC still calls for cleaning and disinfecting the sensor between patients.
- CIncorrect. Sensors are semicritical. The CDC minimum is intermediate-level (tuberculocidal) disinfection, not low-level.
- DIncorrect. Dry wiping is not disinfection. The sensor must be cleaned and then disinfected with an EPA-registered intermediate-level disinfectant.
Question 6
After exposing a full-mouth series, a dental assistant removes her treatment gloves so she can go to the operatory computer, review the images and print a referral. According to CDC guidance, what should she do next?
- APerform hand hygiene right away, before touching the computer or anything else
- BWipe her hands with one of the disinfectant towelettes used on operatory surfaces
- CUse the computer first, then do hand hygiene before seating the next patient
- DWash her hands only if they look soiled; otherwise go straight to the computer
Show answer and explanation
Answer: A) Perform hand hygiene right away, before touching the computer or anything else
CDC directs dental personnel to perform hand hygiene immediately after removing gloves, because hands can be contaminated through glove defects or during removal. Whether hands are visibly soiled affects only the method (soap and water vs. alcohol-based rub).
- ACorrect. CDC calls for hand hygiene immediately after removing gloves. Gloves can have small defects, and hands can become contaminated while taking gloves off.
- BIncorrect. Surface disinfectant wipes are not hand hygiene products. CDC calls for soap and water, or an alcohol-based hand rub when hands are not visibly soiled.
- CIncorrect. Hand hygiene has to happen immediately after removing gloves. Putting it off lets contaminated hands spread microorganisms to the keyboard and other surfaces.
- DIncorrect. Hand hygiene is required after glove removal either way. Visible soiling only decides the method: soap and water instead of an alcohol-based hand rub.
Question 7
When removing PPE, the first item removed is usually the:
- AMask
- BGloves
- CEyewear
- DGown
Show answer and explanation
Answer: B) Gloves
- AIncorrect. Gloves come off first.
- BCorrect. They're the most contaminated.
- CIncorrect. Gloves come off first.
- DIncorrect. Gloves come off first.
Question 8
A PSP plate was exposed inside a barrier envelope and is ready to be processed. Which sequence best prevents contamination of the plate and the scanner?
- AOpen the envelope with treatment gloves and drop the plate into a clean cup without touching it, then remove the gloves, perform hand hygiene, and load the scanner
- BWipe the outside of the sealed envelope with disinfectant, then open it and feed the plate into the scanner while still wearing the treatment gloves
- CRemove the treatment gloves first, perform hand hygiene, and then tear open the envelope with bare hands and slide the plate out to load the scanner
- DOpen the envelope with treatment gloves, spray the bare plate with intermediate-level disinfectant, and then load the scanner wearing the same gloves
Show answer and explanation
Answer: A) Open the envelope with treatment gloves and drop the plate into a clean cup without touching it, then remove the gloves, perform hand hygiene, and load the scanner
Open the exposed PSP barrier with contaminated gloves and let the plate drop out untouched. Then remove the gloves, perform hand hygiene, and handle the plate and scanner with clean hands or fresh gloves.
- ACorrect. The contaminated barrier is handled only with contaminated gloves and the plate falls out without being touched. The scanner is then loaded with clean hands or fresh gloves, so no saliva reaches the plate or the scanner.
- BIncorrect. Wiping the envelope doesn't make the treatment gloves clean. Loading the scanner with gloves worn in the patient's mouth transfers contamination to the plate and the scanner.
- CIncorrect. The outside of the envelope is contaminated with saliva. Opening it with clean bare hands contaminates the hands, and they then carry that contamination to the plate and the scanner.
- DIncorrect. Spraying the plate doesn't fix the contaminated gloves, which still touch the scanner. Unapproved chemicals on the plate's phosphor surface can also damage it; follow the manufacturer's instructions.
Question 9
Which procedure correctly prepares a panoramic unit for the next patient?
- ADisinfect only the bite-block holder, because it is the only part of the unit that comes into contact with the patient's saliva
- BLeave the plastic barriers on all day, and change them only when they are visibly soiled or torn during a procedure
- CRemove the used barriers, clean and disinfect any touched surfaces that were not covered, then put on fresh barriers
- DDetach the chin rest and hand grips and soak them in a high-level chemical sterilant before using them on the next patient
Show answer and explanation
Answer: C) Remove the used barriers, clean and disinfect any touched surfaces that were not covered, then put on fresh barriers
The panoramic unit's contact surfaces are clinical contact surfaces. Between patients, the barriers are replaced, and any touched surfaces that were left uncovered are cleaned and disinfected.
- AIncorrect. The chin rest, head guides, hand grips and controls are also touched by the patient or by the operator's gloves, so they need barriers or disinfection too.
- BIncorrect. CDC says barriers on clinical contact surfaces must be changed between patients, whether or not they look soiled.
- CCorrect. Clinical contact surfaces are barrier-protected or cleaned and disinfected between patients. Used barriers are discarded, uncovered contaminated areas are disinfected, and new barriers go on. A new disposable or reprocessed bite block is used.
- DIncorrect. These are noncritical surfaces that touch only intact skin. A barrier or an EPA-registered hospital disinfectant is enough, so immersion high-level disinfection isn't needed.
Question 10
In the Spaulding classification, a lead apron is:
- ASemi-critical
- BCritical
- CNoncritical
- DSingle-use
Show answer and explanation
Answer: C) Noncritical
- AIncorrect. It doesn't contact mucosa.
- BIncorrect. It doesn't penetrate tissue.
- CCorrect. It contacts only intact skin.
- DIncorrect. It's reusable and noncritical.
RHS: Infection Prevention and Control: FAQs
How much of the CDA exam is RHS: Infection Prevention and Control?
RHS: Infection Prevention and Control is 8% of the CDA exam by the official exam guide's weighting, which on a 245-question form works out to roughly 20 questions. The real exam's exact split varies by form.
What does the RHS: Infection Prevention and Control domain cover?
Infection control applied to radiography: protecting sensors, film and equipment, and handling receptors without cross-contaminating.
How should I study RHS: Infection Prevention and Control for CDA?
Walk through an imaging appointment from set-up to clean-up and note where contamination can spread; questions follow that same order.
Where can I practise more RHS: Infection Prevention and Control questions?
This page has 10 free RHS: Infection Prevention and Control questions with answers. The ExamWize CDA question bank has 46 questions in this domain. Every practice exam result breaks your score down by domain, and Review Mode re-drills the questions you missed.
Other CDA topics
- GC: Evaluation7% of the exam
- GC: Patient Management and Administration7% of the exam
- GC: Chairside Dentistry19% of the exam
- GC: Dental Materials6% of the exam
- ICE: Prevention of Disease Transmission6% of the exam
- ICE: Prevention of Cross-contamination10% of the exam
- ICE: Process Instruments and Devices8% of the exam
- ICE: Occupational Safety and Administration Protocols6% of the exam
- RHS: Purpose and Technique15% of the exam
- RHS: Radiation Characteristics and Protection8% of the exam
Also: 15 free questions across all topics, the CDA cheat sheet and the study guide.
Get RHS: Infection Prevention and Control exam-ready
The full CDA bank has 46 RHS: Infection Prevention and Control questions. Timed practice exams match the real exam's length and domain weights, every result shows your score per domain, and Review Mode re-drills the questions you missed.
Not affiliated with DANB; questions are original, written from the official exam outline, and never copied from the real exam.